Will our TFT automatic nozzles work with the foam eductors my department uses?

Yes, TFT automatic nozzles work with 60, 95, and 125 GPM foam eductors. Just ensure pump pressure is high enough to overcome friction loss and maintain 100 PSI at the nozzle.

EXAMPLE: "We have 60, 95 & 125 GPM eductors, and want to use the TFT’s we use on all of our other attack lines."

The simple answer is YES without a doubt they will work. The TFT works at 100 PSI NOZZLE Pressure which is the same pressure that a manual nozzle would be at if pumped correctly. The important thing is to make SURE that the pump pressure is high enough to cover the friction loss of the eductor and the hose and still have 100 PSI left over for the nozzle. Too much is FAR better than too little. Pump it UP!! Because the educator is such a large restriction over pressuring will cause very little additional flow but it will ensure that there is enough pressure.