---
title: How do I maintain my CrewProtect and StationProtect air filtration units?
description: This guide covers the basic cleaning, cartridge replacement, and filter maintenance steps for TFT’s CrewProtect and StationProtect air decontamination units. Routine upkeep ensures maximum performance and longevity, without any complex service steps.
---

[Skip to content](https://service.tft.com/knowledge/basic-air-filtration-maintenance#main-content)

English

Show submenu for translations

[![TFT logo](https://service.tft.com/hs-fs/hubfs/email-logo.png?width=100&height=36&name=email-logo.png)](https://service.tft.com/knowledge?hsLang=en)

- [Home](https://tft.com/)
- [Store](https://tft.com/product-tag/store)
- [Products](https://tft.com/shop/)
- [Support](https://service.tft.com/home)

Open main navigation

Close main navigation

- [Home](https://tft.com/)
- [Store](https://tft.com/product-tag/store)
- [Products](https://tft.com/shop/)
- [Support](https://service.tft.com/home)
- English
  
  Show submenu for translations

 What are you looking for?

- There are no suggestions because the search field is empty.

1. [Knowledge Base](https://service.tft.com/knowledge?hsLang=en)
2. [Maintenance](https://service.tft.com/knowledge/maintenance?hsLang=en)
3. [Air Filtration](https://service.tft.com/knowledge/maintenance?hsLang=en#air-filtration)

June 24, 2025

# How do I maintain my CrewProtect and StationProtect air filtration units?

## This guide covers the basic cleaning, cartridge replacement, and filter maintenance steps for TFT’s CrewProtect and StationProtect air decontamination units. Routine upkeep ensures maximum performance and longevity, without any complex service steps.

<iframe width="560" height="315" src="https://www.youtube.com/embed/67A5tZTPkC8?si=5wliZG_SxkjJ7yJz" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen style="position: absolute; top: 0px; left: 0px; width: 100%; height: 100%; border: none;"></iframe>

Proper maintenance of your air decontamination units is key to keeping your fire apparatus and station air clean. This guide outlines basic steps to replace filters, wipe down components, and ensure the system stays operational over time.

### Maintenance Overview by Model

#### CrewProtect

- Cartridge Replacement:
  
    1. Loosen the four thumb screws and remove the cover.
    2. Place the new cartridge inside:
       
           - Printed side facing out
           - RFID sensor bottom left
    3. Reattach the cover.

#### CrewProtect Mini

- Cartridge Replacement:
  
    1. Press the two side tabs to release the cartridge.
    2. Discard old cartridge (can be thrown away).
    3. Insert the new cartridge with the RFID side down until it clicks.
    4. Turn the unit on—blue light confirms successful install.

#### StationProtect

- Molecular Cartridges: Replace once per year.
  
    - Open the front panel and remove four cartridges.
    - Slide new ones into place.
- HEPA Filter: Replace annually (same panel).
- Pre-Filter: Replace every 3 months, arrow facing up.

### Cleaning and Upkeep

- CrewProtect:
  
    - Wipe down exterior when you clean cab surfaces.
    - Clean the fan blades a few times per year—best done during cartridge changes.
- StationProtect:
  
    - Wipe aluminum shell down regularly.
    - Unit runs on standard power and sits on caster wheels for mobility.
    - Use a surge protector to prevent power damage.

### Auto-On Behavior

- CrewProtect units run automatically any time the apparatus is on—no need to toggle or switch the device.

### Maintenance Frequency Summary

| Unit | Filter Type | Frequency |
| --- | --- | --- |
| CrewProtect 20 | Cartridge | As indicated by lights |
| CrewProtect 100 | Cartridge | As indicated by lights |
| StationProtect | Molecular Cartridges | Once per year |
| StationProtect | HEPA Filter | Once per year |
| StationProtect | Pre-Filter | Every 3 months |

Always make sure:

- The cover is fully sealed.
- You dispose of used cartridges properly.
- You use a surge protector for StationProtect units.

- [FAQs](https://service.tft.com/knowledge/faqs?hsLang=en#main-content)

    - [Customization & Engraving](https://service.tft.com/knowledge/faqs?hsLang=en#customization-engraving)
    - [Electronic Monitors](https://service.tft.com/knowledge/faqs?hsLang=en#electronic-monitors)
    - [Portable Monitors](https://service.tft.com/knowledge/faqs?hsLang=en#portable-monitors)
    - [Handline Nozzles](https://service.tft.com/knowledge/faqs?hsLang=en#handline-nozzles)
    - [Foam](https://service.tft.com/knowledge/faqs?hsLang=en#foam)
- [Repairs](https://service.tft.com/knowledge/repairs?hsLang=en#main-content)

    - [General](https://service.tft.com/knowledge/repairs?hsLang=en#general)
    - [Ground Monitors](https://service.tft.com/knowledge/repairs?hsLang=en#ground-monitors)
    - [Ball Intake Valves](https://service.tft.com/knowledge/repairs?hsLang=en#ball-intake-valves)
    - [Nozzles](https://service.tft.com/knowledge/repairs?hsLang=en#nozzles)
- [Electronics](https://service.tft.com/knowledge/electronics?hsLang=en#main-content)

    - [Monitors](https://service.tft.com/knowledge/electronics?hsLang=en#monitors)
- [Maintenance](https://service.tft.com/knowledge/maintenance?hsLang=en#main-content)

    - [Air Filtration](https://service.tft.com/knowledge/maintenance?hsLang=en#air-filtration)
    - [Hydrant Valves](https://service.tft.com/knowledge/maintenance?hsLang=en#hydrant-valves)
    - [Nozzles](https://service.tft.com/knowledge/maintenance?hsLang=en#nozzles)

[![Task Force Tips - Fire Fighting Equipment - Logo](https://service.tft.com/hs-fs/hubfs/lettermark-HUBSPOT-LARGE.png?width=150&height=56&name=lettermark-HUBSPOT-LARGE.png "Task Force Tips - Fire Fighting Equipment - Logo")](https://tft.com/)

<https://www.facebook.com/> <https://www.twitter.com/> <https://www.instagram.com/> <https://podcasts.apple.com/> [mailto:email@email.com](mailto:email@email.com)

Copyright © 2025, Task Force Tips LLC

```json
{
  "@context" : "https://schema.org",
  "@type" : "FAQPage",
  "mainEntity" : [ {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "CrewProtect cartridges should be replaced when the indicator light comes on. StationProtect molecular cartridges and HEPA filters are replaced yearly, while pre-filters are changed every 3 months."
    },
    "name" : "How often should I replace my CrewProtect or StationProtect filters?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Gently wipe the fan blades a couple of times a year. The fan is easy to access when the cartridge is removed."
    },
    "name" : "How do I clean the CrewProtect fan?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "No. CrewProtect systems automatically activate whenever the fire apparatus is running—no switch needed."
    },
    "name" : "Do I need to turn on CrewProtect units manually?"
  } ]
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "Organization",
  "logo" : "https://service.tft.com/hs-fs/hubfs/email-logo.png?width=150&height=54&name=email-logo.png",
  "name" : "Task Force Tips",
  "sameAs" : [ "https://www.facebook.com/TaskForceTips", "https://www.linkedin.com/company/task-force-tips", "https://www.youtube.com/@TaskForceTips" ],
  "url" : "https://www.tft.com"
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "WebSite",
  "potentialAction" : {
    "@type" : "SearchAction",
    "query-input" : "required name=search_term_string",
    "target" : "https://service.tft.com/knowledge/kb-search-results?q={search_term_string}"
  },
  "url" : "https://service.tft.com"
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "FAQPage",
  "mainEntity" : [ {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Use the search bar at the top of the page to find repair guides, troubleshooting tips, and service instructions by product name or keyword."
    },
    "name" : "How do I search for repair or service information for my TFT product?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "You can browse our articles on engraving, colored grips, and customizations or contact our Inside Sales team for assistance."
    },
    "name" : "Where can I find support for ordering engraved or colored parts?"
  } ]
}
```